← Back to Blog
MARKET VIEWS

Solar Regulations- Africa

Joseph Saviour · 21 Aug 2025

State
Net metering/Net billing/ Behind the meter
NM Max Cap
Transformer criteria
CD criteria
Banking
TOD wise setllement
Carry forward units to next month in annual billing cycle
Project Investment
Burkina Faso
Behind the meter
Upto CD only
30% of DTC
Max upto 100% CD/SL
N/A
Off‑Peak: 12am to 5pm Peak: 5pm to 12am
No settling of excess units, but tarriff charged is higher for consumption during peak units
Excess units are not settled/ not specified in policy
CAPEX/OPEX both allowed
Kenya
Net metering
1MW
Max upto 100% CD/SL
Monthly
Credited monthly, and if credits are unused then lapsed at end of FY
CAPEX/OPEX both allowed
Tanzania
Net metering
1MW
NA
Max upto 100% CD/SL
Monthly
No TOD slots, based on type of user (R,I,C)
Credited monthly, and if credits are unused then lapsed at end of 3 years or if connection is terminated
CAPEX/OPEX both allowed
Zambia
Net metering
Different categories, largest one allows upto 5MW
Not specified
Max upto 100% CD/SL
NA
No TOD slots, tariff rates are flat and based on categories
Excess units don't rollover monthly, but monetary credit awarded based on type of account (pre or postpaid)
CAPEX/OPEX both allowed
Botswana
Net metering
1MW
90% of DTC
Max upto 110% CD/SL
Monthly
No TOD slots
Excess units are credited, and unused units are settled at the AC rate at the end of FY.
CAPEX/OPEX both allowed
Rwanda
Not yet operational
NA
Max upto 100% CD/SL
NA
No TOD slots, tariff rates are flat and based on categories
NA
CAPEX allowed for CPP, but OPEX requires license from REG
Uganda
Net metering
0.5 MW
Max upto 100% CD/SL
Monthly
Credited monthly, and if credits are unused then lapsed at end of FY